{"id":2651,"date":"2026-09-16T13:23:14","date_gmt":"2026-09-16T13:23:14","guid":{"rendered":"https:\/\/staging.ardeloem.co.uk\/?page_id=2651"},"modified":"2026-09-27T10:03:26","modified_gmt":"2026-09-27T10:03:26","slug":"hose-assembly-procedure","status":"publish","type":"page","link":"https:\/\/staging.ardeloem.co.uk\/?page_id=2651","title":{"rendered":"Hose assembly procedure"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>N.B.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This information is provided for general guidance only and is not a substitute for the manufacturer\u2019s instructions, a site-specific risk assessment, applicable UK requirements or advice from a competent hydraulic professional. Hydraulic systems can contain high pressure and stored energy and may cause serious injury or death if incorrectly selected, assembled, installed, inspected or maintained. Never work on a pressurised system. Isolate, lock out and depressurise equipment before work, and use correctly specified, compatible components and approved assembly and testing procedures. If in doubt, stop work and seek competent professional advice. To the fullest extent permitted by law, Ardel OEM Limited accepts no responsibility for reliance on this information, subject to any liability that cannot lawfully be excluded or limited.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Assembling Bridgestone R12, R13, and R15 spiral-wire hoses with Intertraco fittings requires strict adherence to manufacturer instructions, standards, and safe practices. This procedure outlines safe assembly and helps reduce leaks, blow-offs, and injury.&nbsp;<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Understand the Hose Standards: R12, R13, R15<\/strong><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Bridgestone R12, R13, and R15 are spiral-wire hydraulic hoses for very high- and ultra-high-pressure use.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>SAE 100 R12: Four-spiral heavy-wire hose for very high-pressure lines, rated up to about 40 MPa \/ 5,800 psi depending on size.<\/li>\n\n\n\n<li>SAE 100 R13: Multi-spiral-wire hose, usually four or six layers, for ultra-high-pressure circuits up to about 45 MPa \/ 6,500 psi.<\/li>\n\n\n\n<li>SAE 100 R15: Multi-spiral-wire hose for ultra-high-pressure, large-bore applications, often rated to 42 MPa \/ 6,000 psi or higher.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">All three require approved two-piece interlock, skive, or no-skive crimp fittings that engage all reinforcement layers.&nbsp;<\/p>\n\n\n\n<ol start=\"2\" class=\"wp-block-list\">\n<li><strong>Verify Compatibility: Hose and Fitting Match<\/strong><\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Confirm the Bridgestone hose and Intertraco fittings are approved for use together.<\/li>\n\n\n\n<li>Check the hose layline for SAE\/EN family, dash size, and pressure rating.<\/li>\n\n\n\n<li>Check the Intertraco chart for the approved hose type and fitting series.<\/li>\n\n\n\n<li>Confirm the fitting matches the hose working pressure and dash size.<\/li>\n\n\n\n<li>Rule: Do not mix manufacturers unless both approve the combination.&nbsp;<\/li>\n<\/ul>\n\n\n\n<ol start=\"3\" class=\"wp-block-list\">\n<li><strong>Personal Protective Equipment (PPE) and Workspace Safety<\/strong><\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Warning: Failed high-pressure assemblies can cause severe injury.<\/li>\n\n\n\n<li>Wear safety glasses, gloves, and steel-toe boots.<\/li>\n\n\n\n<li>Work in a clean, well-lit, hazard-free area.<\/li>\n\n\n\n<li>Ensure the crimper is calibrated and maintained.<\/li>\n\n\n\n<li>Keep a guarded pressure test rig for post-assembly testing.&nbsp;<\/li>\n<\/ul>\n\n\n\n<ol start=\"4\" class=\"wp-block-list\">\n<li><strong>Hose Preparation<\/strong><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">4.1 Measure and Cut<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Measure assembly length, allowing for fitting insertion lengths.<\/li>\n\n\n\n<li>Cut the hose square with a hose cutter or saw; avoid crushing or fraying.<\/li>\n\n\n\n<li>Deburr the cut end lightly if needed without damaging the inner tube or wire spirals.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">4.2 Skiving If Required<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>For skive fittings, remove the cover to the length specified by Intertraco.<\/li>\n\n\n\n<li>For no-skive fittings, ensure the hose outer diameter matches the ferrule design range.&nbsp;<\/li>\n<\/ul>\n\n\n\n<ol start=\"5\" class=\"wp-block-list\">\n<li><strong>Fitting Preparation and Assembly<\/strong>&nbsp;<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Intertraco supplies one- and two-piece crimp fittings for spiral hoses.<\/li>\n\n\n\n<li>One-piece fittings: Combined stem and ferrule, used where approved.<\/li>\n\n\n\n<li>Two-piece fittings: Separate stem and ferrule\/sleeve, typically required for R12\/R13\/R15 spiral hoses.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">5.1 Lubrication<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Lightly lubricate the stem and hose I.D. with approved hydraulic oil or assembly lubricant.<\/li>\n\n\n\n<li>Do not use petroleum-based lubricants if incompatible with the hose inner tube.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">5.2 Insert Fitting Stem<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Push the stem fully into the hose until it bottoms out against the internal shoulder.<\/li>\n\n\n\n<li>Ensure the hose sits square on the stem and is not twisted.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">5.3 Position Ferrule \/ Sleeve<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Slide the ferrule over the hose and seat it as specified.<\/li>\n\n\n\n<li>For two-piece fittings, ensure the interlock features align correctly with the stem.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">5.4 Crimping Procedure<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Use Intertraco\u2019s chart to select the correct die set and crimp diameter. Approved crimp charts can be downloaded from this web site. <strong><a href=\"https:\/\/staging.ardeloem.co.uk\/?page_id=1526\">Click here<\/a><\/strong>.<\/li>\n\n\n\n<li>Place the assembly in the crimper with the fitting properly supported.<\/li>\n\n\n\n<li>Select the die set matching the hose dash size and fitting series.<\/li>\n\n\n\n<li>Crimp to the specified diameter, then measure with callipers.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">5.5 Inspect the crimp:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>No visible gaps between ferrule and hose.<\/li>\n\n\n\n<li>No excessive rubber extrusion.<\/li>\n\n\n\n<li>Crimp diameter within tolerance.<\/li>\n\n\n\n<li>Note: Incorrect crimp diameter can cause leaks or blow-off.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">5.6 Post-Crimp Inspection<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Visually inspect for:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Correct fitting orientation, with no twist against the hose layline.<\/li>\n\n\n\n<li>No damage to the hose cover or fitting.<\/li>\n\n\n\n<li>Correct crimp position and diameter.<\/li>\n\n\n\n<li>Remove excess lubricant and debris.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">5.7 Pressure Testing Before Installation<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Install the assembly in a guarded test rig.<\/li>\n\n\n\n<li>Pressurise to 1.5 \u00d7 working pressure and hold for the specified time.<\/li>\n\n\n\n<li>Check for leaks at fittings, bulging or distortion, and fitting movement.<\/li>\n\n\n\n<li>Depressurise fully before handling.&nbsp;<\/li>\n<\/ul>\n\n\n\n<ol start=\"6\" class=\"wp-block-list\">\n<li><strong>Installation on Machine<\/strong><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">6.1 Route the hose to avoid:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Tight bends near the ferrule.<\/li>\n\n\n\n<li>Abrasion against moving parts or sharp edges.<\/li>\n\n\n\n<li>Twisting; use the layline as a reference.<\/li>\n\n\n\n<li>Tighten end connections to the specified torque with a calibrated torque wrench.<\/li>\n\n\n\n<li>Under-tightening: leaks.<\/li>\n\n\n\n<li>Over-tightening: cracked fittings or overstressed threads.&nbsp;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">6.2 System Checkout and Air Removal<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Bleed air according to equipment manufacturer instructions.<\/li>\n\n\n\n<li>Cycle at low pressure, then increase gradually while checking for leaks.<\/li>\n\n\n\n<li>Safety: Never touch pressurised hoses or couplings; use cardboard to check for leaks if needed.&nbsp;<\/li>\n<\/ul>\n\n\n\n<ol start=\"7\" class=\"wp-block-list\">\n<li><strong>Documentation and Traceability<\/strong><\/li>\n<\/ol>\n\n\n\n<p class=\"has-text-align-left wp-block-paragraph\">Record:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hose type and batch\/lot number.<\/li>\n\n\n\n<li>Fitting part numbers.<\/li>\n\n\n\n<li>Crimp diameter and date.<\/li>\n\n\n\n<li>Test pressure and results.<\/li>\n\n\n\n<li>Label the assembly if required by your quality system or customer specifications.&nbsp;<\/li>\n<\/ul>\n\n\n\n<ol start=\"8\" class=\"wp-block-list\">\n<li><strong>Key Safety Reminders<\/strong><\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Never assemble or test a hose assembly without verified compatibility data.<\/li>\n\n\n\n<li>Never exceed the hose\u2019s maximum working pressure or temperature range.<\/li>\n\n\n\n<li>Always use torque wrenches and calibrated crimping equipment.<\/li>\n\n\n\n<li>Always depressurise before adjusting or tightening connections.<\/li>\n\n\n\n<li>Following Bridgestone specifications, Intertraco recommendations, and SAE\/ISO best practices helps ensure safe, reliable high-pressure hose assemblies.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>N.B. This information is provided for general guidance only and is not a substitute for the manufacturer\u2019s instructions, a site-specific risk assessment, applicable UK requirements or advice from a competent hydraulic professional. Hydraulic systems can contain high pressure and stored energy and may cause serious injury or death if incorrectly selected, assembled, installed, inspected or [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2266,"parent":2900,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_themeisle_gutenberg_block_has_review":false,"footnotes":""},"class_list":["post-2651","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=\/wp\/v2\/pages\/2651","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2651"}],"version-history":[{"count":5,"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=\/wp\/v2\/pages\/2651\/revisions"}],"predecessor-version":[{"id":2917,"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=\/wp\/v2\/pages\/2651\/revisions\/2917"}],"up":[{"embeddable":true,"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=\/wp\/v2\/pages\/2900"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=\/wp\/v2\/media\/2266"}],"wp:attachment":[{"href":"https:\/\/staging.ardeloem.co.uk\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2651"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}