10 steps to ‘healthy hydraulics’

N.B.

This information is provided for general guidance only and is not a substitute for the manufacturer’s instructions, a site-specific risk assessment, applicable UK requirements or advice from a competent hydraulic professional. Hydraulic systems can contain high pressure and stored energy and may cause serious injury or death if incorrectly selected, assembled, installed, inspected or maintained. Never work on a pressurised system. Isolate, lock out and depressurise equipment before work, and use correctly specified, compatible components and approved assembly and testing procedures. If in doubt, stop work and seek competent professional advice. To the fullest extent permitted by law, Ardel OEM Limited accepts no responsibility for reliance on this information, subject to any liability that cannot lawfully be excluded or limited.

10 steps for healthy hydraulics in mobile equipment

For an excavator working in the UK, “healthy hydraulics” means reliable performance, controlled contamination, safe hose management and documented maintenance. Use the excavator manufacturer’s maintenance schedule as the controlling document; the following ten-step programme is a practical framework, not a substitute for the OEM manual or a competent engineer’s inspection.

  1. Complete a pre-start inspection

Before each shift, and with the machine safely parked, walk around the excavator and check:

  • Hydraulic hoses for leaks, cuts, abrasion, crushing, kinks, twisting, exposed reinforcement or blistering.
  • Fittings, clamps, guards and hose routing.
  • Hydraulic cylinders for leaking seals, damaged rods or pitting.
  • The tank, pump, valves, swivel joint and undercarriage for oil leaks.
  • Oil level and visible signs of contamination.
  • Unusual damage after impact, heavy digging or attachment changes.

Never search for a high-pressure leak with your hand. Hydraulic fluid can penetrate skin through a pinhole and cause serious injury, including amputation; HSE treats suspected injection injuries as an emergency.hse.gov+1

  1. Isolate pressure before maintenance

Before disconnecting a hose, filter, valve, cylinder or other hydraulic component:

  1. Park on stable ground.
  2. Lower the boom, arm and bucket or support them mechanically.
  3. Stop the engine.
  4. Isolate and lock off the machine where necessary.
  5. Relieve hydraulic and accumulator pressure according to the manufacturer’s procedure.
  6. Confirm that stored energy has been released.
  7. Prevent unintended movement or restart.

HSE advises isolating plant and pipelines containing pressurised fluid and ensuring that maintenance is carried out by competent people.hse

  1. Control fluid contamination

Contamination is one of the main causes of hydraulic component failure. Prevent dirt, water and metal particles entering the system by:

  • Cleaning around filler caps, breathers, filters and hose connections before opening them.
  • Using clean, dedicated transfer equipment.
  • Keeping replacement oil in sealed, labelled containers.
  • Capping hoses and ports immediately after disconnection.
  • Avoiding open funnels, dirty rags and unprotected containers.
  • Inspecting tank breathers and filler strainers.
  • Keeping the machine and cylinder rods clean in muddy conditions.

Do not assume that new oil is clean enough for a sensitive hydraulic system. Filter new oil when the OEM or fluid supplier specifies a cleanliness requirement.

  1. Monitor oil condition and cleanliness

Establish a fluid-analysis programme appropriate to the machine’s duty cycle. Sample from a consistent, representative point and monitor:

  • Particle count or cleanliness code.
  • Water contamination.
  • Viscosity.
  • Oxidation and degradation.
  • Wear metals.
  • Additive condition.
  • Evidence of incorrect or mixed fluids.

Trend the results rather than reacting to a single sample. A worsening trend can identify pump, motor, cylinder or filter problems before loss of performance or component failure. Use the oil and filter-change intervals specified by the excavator manufacturer; a general interval should not override the OEM schedule.develon-ce

  1. Replace filters correctly

Check hydraulic filters at the manufacturer’s specified operating-hour intervals and whenever differential-pressure indicators or warning systems require action.

When changing a filter:

  • Use the correct part and filtration rating.
  • Clean the filter housing before opening it.
  • Inspect the removed filter for metal, seal material or unusual debris.
  • Confirm that seals and O-rings are correctly fitted.
  • Prevent dirt entering during the change.
  • Record operating hours and findings.
  • Investigate abnormal contamination rather than simply fitting a new filter.

A filter change that repeatedly becomes necessary ahead of schedule may indicate component wear, seal failure, poor cleaning practice or water ingress.

  1. Manage hoses and assemblies

Replace a hose assembly immediately if it shows:

  • Leakage from the hose wall or fitting.
  • Exposed reinforcement.
  • Severe abrasion, cuts, crushing or kinking.
  • Blistering, cracking, hardening or heat damage.
  • Fitting slippage.
  • Twisting or flattening.
  • Chemical degradation.
  • Damage caused by an attachment or moving structure.

Check that replacement assemblies have the correct bore, pressure rating, temperature range, fluid compatibility, fitting type, length and minimum bend radius. Do not patch or tape a pressurised hydraulic hose. Repeated failure in the same place requires a routing, clamping, guarding or specification review—not repeated like-for-like replacement.

  1. Check routing, movement and protection

Large excavators subject hoses to vibration, flexing, impact, heat, mud and movement across the boom, arm and attachment. Verify that:

  • Hoses do not rub against steelwork or adjacent hoses.
  • The bend radius is not exceeded.
  • Hoses are not pulled tight at full boom, arm or bucket movement.
  • Hoses are not twisted during installation.
  • Clamps and supports are correctly positioned.
  • Protective sleeves or guards are fitted where abrasion or impact is foreseeable.
  • Hose movement does not load the fitting.
  • Attachment couplings and auxiliary lines are correctly connected.

Check the machine through its full range of movement, using a safe procedure and keeping people clear of moving parts. ISO 4413 provides general hydraulic-system safety principles for design, installation, operation and maintenance.iso+1

  1. Control heat and operating conditions

Excessive heat accelerates oil degradation, damages seals and shortens hose life. Monitor for:

  • High oil-temperature alarms.
  • Blocked coolers or radiators.
  • Restricted airflow.
  • Low oil level.
  • Relief valves operating excessively.
  • Incorrect oil viscosity.
  • Internal leakage in pumps, motors or valves.
  • Continuous operation at high load.

Clean cooling surfaces using the manufacturer’s method, without bending fins or driving contamination further into the cooler. If the system is overheating, identify the cause rather than simply changing the oil.

  1. Test performance and investigate changes

Operators and technicians should record changes such as:

  • Slower cycle times.
  • Loss of breakout force.
  • Increased engine load.
  • Erratic or jerky movements.
  • Excessive pump noise or cavitation.
  • Rising oil temperature.
  • Drift when controls are neutral.
  • Repeated hose or seal failures.
  • New vibration or pressure alarms.

Use appropriate diagnostic equipment and competent personnel to check pressures, flow, temperature and leakage. Do not increase relief-valve settings or alter control valves as a trial measure; incorrect adjustments can damage the machine and create unsafe pressure conditions.

  1. Document maintenance and review trends

Maintain a hydraulic health record containing:

  • Daily inspection results.
  • Operating hours and duty conditions.
  • Hose and filter replacements.
  • Oil additions and changes.
  • Fluid-analysis reports.
  • Pressure and temperature readings.
  • Contamination findings.
  • Recurring faults.
  • Component part numbers and date codes.
  • Root-cause actions.
  • Competent-person inspections and test results.

Review the information periodically. For example, three hose failures on the same boom section may indicate poor routing or abrasion; repeated pump contamination may indicate a failing component or ineffective cleanliness controls.

UK workplace equipment must be maintained in a safe condition and inspected where deterioration could create a significant risk under PUWER. HSE also stresses competent maintenance, safe isolation and action on reported defects.hse+2

Suggested maintenance rhythm

FrequencyMinimum focus
Before each shiftWalk-around, hose and cylinder checks, oil level, visible leaks, damage and warning indicators
Weekly or according to site riskHose routing, clamps, guards, fittings, attachment connections, cooler cleanliness and abnormal noises
At scheduled service intervalsFilters, oil sampling, lubrication, pressure/temperature checks and manufacturer-specific inspections
After a major impact or hose failureFull contamination check, component inspection, root-cause review and safe recommissioning
PeriodicallyReview fluid-analysis trends, recurring failures, replacement intervals, competence and PUWER records

The safest operating rule is simple: stop and isolate the excavator if there is a dangerous leak, uncontrolled movement, severe hose damage, abnormal hydraulic noise, overheating or suspected high-pressure injection injury. Do not return the machine to service until the fault has been assessed and corrected by a competent person.